Capabilities
Drafting
Drafting is available in enterprise preview and may not be enabled for your organization. Contact your Nomic account team for access.
Nomic drafts new drawings and revises existing ones to your standard, reviewing its work as it goes. It drafts in three places:
| Where | Use it to |
|---|---|
| Cloud CAD | Draft or revise DWG, DXF, and DGN drawings in Nomic's cloud-based CAD engine, and convert PDFs, scans, and photos to CAD. No desktop software needed. |
| Revit add-in | Change the model open in Revit: fix clashes, respond to comments, set up sheets, and build families. |
| AutoCAD add-in | Change the CAD file open in AutoCAD, including MEP objects, with your approval before each change. |
In all three, the request decides most of the result. The rest of this page lists what to include and gives full example requests you can adapt.
What to include
| Include | Why it matters |
|---|---|
| Your standard | Attach a sheet in your standard, your title block, or your template. Nomic draws on your layers, blocks, text and dimension styles, and title block. Without one, it uses discipline layer names and the Nomic title block. |
| The deliverable | Name the sheet number, sheet size, scale, and format (DWG, DXF, or DGN). Without a scale, Nomic picks the largest standard scale that fits the sheet. |
| The full scope | Say "every room", "all three levels", or "each sheet in the set" when you mean it. Nomic lists every item it will draw and checks the saved drawing against that list. |
| Units and conventions | On a US project Nomic defaults to feet and inches. Say so if you want metric, and say whether a span is clear or to centerlines. |
| Title block fields | Give the project, client, project number, address, date, and drawn by. A field Nomic can't fill reads TBC. |
| What to do with what's left | Say what Nomic should do with items it can't resolve, such as "list the rest for the structural engineer." |
Example requests
New drawings
Draft an enlarged mechanical room plan for Level 1 on M-501 at 1/4" = 1'-0" on an ARCH D sheet. Use the attached M-101 for our layers, title block, and text styles. Show the two boilers, the expansion tank, and both pumps from the attached equipment schedule, with 3'-0" service clearance in front of each. Tag every piece of equipment. Project: Riverside Middle School, project number 24-118, drawn by JK.
Add a detail to M-601 for the rooftop unit curb, matching the layers, line weights, hatching, and text of the other details on the sheet. Dimension the curb height and the flashing, and title it with its scale.
Revisions
Revise M-201 per the attached plan review comments. Address each comment in our layers, cloud each change, add Revision 2 dated 11/24/2026 to the revision block, and draft a response letter that says how each comment was addressed.
On every sheet in this set, change the project number to 24-118B and the issue date to 12/01/2026. Don't move or change anything else.
Nomic edits the existing drawing in place and saves it as a new version in the format it came in. It changes only what you asked for, and names anything else the change affects, such as a dimension string that no longer adds up.
PDFs, scans, and photos
Convert the attached PDF of E-101 to DWG. Keep the layers from the PDF and check each detail's scale against the scale notes.
Turn this scanned 1998 floor plan into an editable DWG. The corridor is 8'-0" wide. Redraw the walls, doors, and room names as linework on our layers, not as a traced image.
A vector PDF converts with its linework, text, and scales. A scan or photo is traced into a measured underlay. Ask for editable linework when you want it redrawn. A photo carries no scale, so give one known dimension.
Revit add-in
Address comment 4: add fire dampers wherever ductwork crosses the 2-hour corridor walls on Level 3. Cloud the changes on M-301 and add them to Revision 3.
Find where ductwork clashes with structural framing on Level 2, with 1" clearance. Fix the ones you can by rerouting the duct, and list the rest with their locations for the structural engineer.
Build a parametric family for our 24x24 ceiling diffuser with Width, Length, and Neck Diameter parameters and a duct connector on the neck. Flex the types, then load it into the project.
AutoCAD add-in
Here's reviewer comment 4: the 12x10 branch to rooms 214–216 runs through shaft S-2. Reroute it around the shaft on M-201 in my layers and cloud the change.
Check this drawing for layer and block problems and list what you find. Don't change anything yet.
Iterating
- Follow up in the same conversation. Nomic keeps the drawing and its decisions in context: "move the pump to the north wall and add a dimension to the column grid."
- Answer clarifying questions. When a request is ambiguous, Nomic asks before it draws.
- Read the assumptions. Nomic says in its reply which assumptions it made. Correct any that are wrong in your next message.
- Review before issue. Open the plotted PDF and check every drawing before it is issued.